What is the cause of air conditioning leakage? How should it be solved?

I believe you are no stranger to air conditioning. With the improvement of living standards, every household has installed air conditioning. Air conditioning is an essential household appliance for us to live at home. No matter in winter or summer, air conditioning is indispensable. It is inevitable that air conditioning will fail in use. What is the reason for the leakage of air conditioning? Understand these days will be comfortable!

What is the cause of air conditioning leakage?

1. Causes of heat exchanger

The stolen goods of the filter screen are seriously not cleaned in time or the filter screen is damaged, resulting in the deformation of the evaporator, so that it cannot drip into the tank in time; Insufficient freon in the air conditioning system causes the evaporator of the indoor unit to freeze, and water droplets cannot be dropped into the water-saving pan; The material of the air conditioner is not very good. The internal setting is unreasonable. The water can't flow into the sink, so it stays along the plastic shell.

2. The air conditioner was not firmly installed during installation, and the displacement occurred after a long time of use, resulting in the change of the position of the drainage pipe and the difficulty of drainage.

3. Quality problems of drainage pipeline

Some drainage pipes are of poor quality and easy to age and relax, resulting in bending of pipe shape and poor drainage.

4. Dew on piping

Because the quality of the insulation material on the pipeline is too poor or too thin, dew is easy to appear when the refrigerant in the pipeline passes through.

5. The outdoor drainage pipe is blocked

If the outdoor drainage pipe is blocked, the water can not be drained, resulting in overflow.

How to solve the leakage of air conditioner?

1. The water leakage of the air conditioner caused by the unstable installation of the air conditioner must be adjusted during the maintenance, and the air conditioner should be reinforced at the same time. If the user can't adjust the horizontal position of the air conditioner, it's better to ask a professional to help.

2. If the drainage of the air conditioning drainage pipe is poor, it must be necessary to replace the drainage pipe. When adjusting the air conditioning drainage pipe, it can be coated with waterproof glue at its connection and wrapped with waterproof tape. The newly installed drainage pipe must be set to ensure that it has a certain downward slope, so that the water can be discharged to the outdoor designated position under the action of gravity.

3. In case of pipe condensation and blocked drainage pipe, the first thing to be replaced is the insulation layer on the pipe to ensure that the pipe can be fully insulated and the pipe is not easy to condense. Then, the drainage pipe needs to be dredged to ensure the smooth drainage of the drainage pipe, so that the water leakage of the air conditioner can be solved.

4. When the air conditioning heat exchanger drips water, it is mainly to check the filter screen of the air conditioner. If there is too much dust on the filter screen of the air conditioner, it is necessary to clean the filter screen of the air conditioner. If the filter screen is damaged, it must be replaced. When cleaning the filter screen, the interior of the air conditioner should also be cleaned to ensure that the evaporator of the air conditioner is clean and restore the hydrophilicity of the hydrophilic aluminum foil, so that the dew can flow into the water receiving tank through the evaporator.

What are the precautions for the use of air conditioner?

1. The power supply voltage shall not fluctuate too much (a fluctuation of ± 10% is allowed), and the air conditioner shall be powered by a special line, using a single-phase three hole socket, and the plug shall be inserted to the bottom.

2. The shell of the indoor unit shall be cleaned frequently. Generally, it can be wiped with a clean dry cloth or neutral detergent. It is absolutely not allowed to wash it directly with water. If it is wiped with a cloth, it shall also be carried out after power failure.

3. The indoor temperature cannot be adjusted too low, otherwise it will be harmful to human body. The set temperature should be adjusted appropriately.

4. If the indoor temperature is set too high, it can be reduced.

5. The effective use of timer can achieve the effect of energy saving and comfort.

6. The personnel in the air-conditioned room shall not be too many or crowded, otherwise the cooling capacity is insufficient and the temperature is difficult to drop;

7. Doors and windows of the room shall not be opened and closed frequently, and personnel shall not enter and leave frequently to avoid loss of air conditioning;

8. The glass windows must be closed tightly and tightly, and double-layer white curtains should be hung inside to reflect part of the penetrated light and heat;

9. The window can be opened briefly during indoor ventilation, and the window opening time is generally no more than 10 minutes;

10. The air filter should be cleaned regularly, otherwise the air flow is blocked, resulting in insufficient air volume and elevated room temperature; Clean the air conditioner in time.